MIL-PRF-19500/382J
*
4.5.6 Delta requirements. Delta requirements shall be as specified below. (1) (2) (3) (4)
Step
Inspection
MIL-STD-750
Symbol
Limit
Unit
Method
Conditions
Bias condition D:
ĆICBO1
1
Collector to base
3036
100 percent of
IE = 0
cutoff current
initial value or
VCB = -15 V dc
2N2944A
.2 nA
VCB = -25 V dc
2N2945A, AM,
.2 nA
UB, and AUBM
VCB = -40 V dc
2N2946A
.5 nA
VEC = -0.5 V dc;
ĆhFE(inv)1
2
Forward-current
3076
25 percent of
IE = 200 µA dc;
transfer ratio
initial value.
(see 4.5.3)
(inverted
connection)
(1) The electrical measurements for table E-VIa (JANS) of MIL-PRF-19500 are as follows: Subgroup 5, see 4.5.6,
steps 1 and 2.
(3) The electrical measurements for table E-VII of MIL-PRF-19500 are as follows: Subgroup 6, step 1 and step 2
(JANS).
*
12