MIL-PRF-19500/382J
3.4 Interface and physical dimensions. Interface and physical dimensions shall be as specified in
3.4.1 Lead finish. Lead finish shall be solderable in accordance with MIL-PRF-19500, MIL-STD-750, and herein.
Where a choice of lead finish is desired, it shall be specified in the acquisition document (see 6.2).
* 3.5 Radiation hardness assurance (RHA). Radiation hardness assurance requirements, PIN designators, and
test levels shall be as defined in MIL-PRF-19500.
3.6 Electrical performance characteristics. Unless otherwise specified herein, the electrical performance
3.7 Electrical test requirements. The electrical test requirements shall be as specified in table I, and herein.
* 3.8 Marking. Marking shall be in accordance with MIL-PRF-19500. At the option of the manufacturer, marking
may be omitted from the body, but shall be retained on the initial container. The radiation hardness designator M, D,
P, L, R, F, G, or H shall immediately precede (or replace) the device "2N" identifier (depending upon degree of
abbreviation required).
3.9 Workmanship. Semiconductor devices shall be processed in such a manner as to be uniform in quality and
shall be free from other defects that will affect life, serviceability, or appearance.
4. VERIFICATION
*
4.1 Classification of inspections. The inspection requirements specified herein are classified as follows:
a. Qualification inspection (see 4.2).
b. Screening (see 4.3).
c. Conformance inspection (see 4.4 and table I and II).
*
4.2 Qualification inspection. Qualification inspection shall be in accordance with MIL-PRF-19500 and as
specified herein.
4.2.1. JANHC and JANKC qualification. JANHC and JANKC qualification inspection shall be in accordance with
MIL-PRF-19500.
* 4.2.2 Group E qualification. Group E inspection shall be performed for qualification or re-qualification only. In
case qualification was awarded to a prior revision of the specification sheet that did not request the performance of
table III tests, the tests specified in table III herein that were not performed in the prior revision shall be performed on
the first inspection lot of this revision to maintain qualification.
7
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business