MIL-PRF-19500/392J
* TABLE I. Group A inspection - Continued.
Inspection 1/
MIL-STD-750
Symbol
Limit
Unit
Method
Conditions
Min
Max
Subgroup 2 - Continued.
Emitter to base cutoff
3061
50
nA dc
Bias condition D; VEB = 3.5 V dc.
IEBO2
current
Forward-current transfer
3076
VCE = 10 V dc; IC = 0.1 mA dc.
hFE1
ratio
2N3485A
40
2N3486A
75
Forward-current transfer
3076
VCE = 10 V dc; IC = 1.0 mA dc.
hFE2
ratio
2N3485A
40
2N3486A
100
Forward-current transfer
3076
VCE = 10 V dc; IC = 10 mA dc.
hFE3
ratio
2N3485A
40
2N3486A
100
Forward-current transfer
3076
VCE = 10 V dc; IC = 150 mA dc
hFE4
ratio
pulsed (see 4.5.1).
40
120
2N3485A
2N3486A
100
300
Forward-current transfer
3076
VCE = 10 V dc; IC = 500 mA dc
hFE5
ratio
pulsed (see 4.5.1).
2N3485A
40
2N3486A
50
Saturation voltage and
3071
0.4
V dc
IC = 150 mA dc; IB = 15 mA dc;
VCE(SAT)1
resistance
pulsed (see 4.5.1).
Saturation voltage and
3071
1.6
V dc
IC = 500 mA dc; IB = 50 mA dc;
VCE(SAT)2
resistance
pulsed (see 4.5.1).
See footnotes at end of table.
9
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business