MIL-PRF-19500/399F
* TABLE II. Group D inspection and end-point limits.
Inspection 1/ 2/ 3/
Symbol
Unit
MIL-STD-750
Limits
Method
Conditions
Min
Max
Subgroup 1 4/
Neutron Irradiation
1017
Neutron exposure VCES = 0 V
Breakdown voltage,
3011
Bias condition D; IC = 10 uA dc,
V(BR)CEO
12
V dc
collector to emitter
pulsed (see 4.5.1)
Collector to base cutoff
3036
Bias condition D,
ICBO
20
uA dc
current
VCB = 20 V
3061
Bias condition D, VEB = 4.5 V dc
Emitter to base cutoff
IEBO
20
ľA dc
current
Collector to emitter
3041
Bias condition A;
ICEX1
2.0
ľA dc
cutoff current
VCE = 10 V dc, VBE = 0.4 V dc
Collector to emitter
3041
Bias condition A;
ICEX2
10
nA dc
cutoff current
VCE = 10 V dc, VBE = 2.0 V dc
Forward-current transfer
3076
VCE = 1 V dc, IC = 1.0 mA dc
[hFE1]
[20] 5/
ratio
Forward-current transfer
3076
VCE = 1 V dc, IC = 10 mA dc,
[hFE2]
[30] 5/
300
ratio
pulsed (see 4.5.1)
Forward-current transfer
3076
VCE = 1 V dc, IC = 30 mA dc,
[hFE3]
[15] 5/
ratio
pulsed (see 4.5.1)
Collector to emitter
3071
IC = 1.0 mA dc; IB = 0.1 mA dc
VCE(sat)1
0.23
V dc
saturated voltage
Collector to emitter
0.35
3071
V dc
IC = 30 mA dc; IB = 3 mA dc,
VCE(sat)2
saturated voltage
pulsed (see 4.5.1)
Base emitter voltage
0.92
3066
V dc
Test condition B, VCE = 1.0 V dc,
VBE1
(non saturated)
IC = 1.0 mA dc
Base emitter voltage
1.15
3066
V dc
Test condition B, VCE = 1.0 V dc,
VBE2
(non saturated)
IC = 30 mA dc
See footnotes at end of table.