* TABLE III. Groups B, C, and E delta end-point inspection measurements. 1/ 2/ 3/ 4/
Step
Inspection
MIL-STD-750
Symbol
Limit
Unit
Method
Conditions
Min
Max
Bias condition A, VCE = 10 V dc,
1.
Collector to emitter
100 percent of initial
3041
ĆICEX2
cutoff current
value or 2 nA dc,
VBE = 2.0 V dc
5/
whichever is greater;
VCE = 1.0 V dc; IC = 10 mA dc;
2.
Forward current
3076
±20 percent change
ĆhFE2 5/
transfer ratio
from initial value
pulsed (see 4.5.1)
1/
The delta measurements for table VIa (JANS) of MIL-PRF-19500 are subgroup 4 and 5, see table III herein, all
steps.
2/
The delta measurements for group B of 4.4.2.2 herein (JAN, JANTX, and JANTXV) are: Step 1, 2, and 3 of
4.4.2.2, see table III herein, all steps.
3/
The delta measurements for table E-VII of MIL-PRF-19500, Subgroup 6, all steps:
4/
The delta measurements for table E-IX of MIL-PRF-19500 are: Subgroups 1 and 2, see table III herein, all
steps.
5/
Devices which exceed the table I limits herein for this test shall not be accepted.