MIL-PRF-19500/399F
4.3 Screening (JANS, JANTX and JANTXV levels only). Screening shall be in accordance with table E-IV of
MIL-PRF-19500 and as specified herein. The following measurements shall be made in accordance with table I
herein. Devices that exceed the limits of table I herein shall not be acceptable.
Screen (see table E-IV
Measurement
of MIL-PRF-19500)
JANS level
JANTX and JANTXV levels
3c
Thermal impedance
Thermal impedance
Method 3131 of MIL-STD-750 (see
Method 3131 of MIL-STD-750 (see
4.3.3).
4.3.3). (1)
9
Not applicable
ICEX2 and hFE2
VCB = 12 V, 48 hours minimum.
VCB = 12 V, 48 hours minimum.
10
11
ICEX2 and hFE2
ICEX2 and hFE2
ĆICEX2 = 100 percent of initial value
or 2 nA dc, whichever is greater;
ĆhFE2 = ±20 percent.
12
See 4.3.1
See 4.3.1
Subgroup 2 of table I herein;
13
Subgroups 2 and 3 of table I herein;
ĆICEX2 = 100 percent of initial value or 2
ĆICEX2 = 100 percent of initial value
nA dc, whichever is greater;
or 2 nA dc, whichever is greater;
ĆhFE2 = ±20 percent.
ĆhFE2 = ±20 percent.
14
Required.
Required.
(1) Shall be performed anytime after temperature cycling, screen 3a; and does not need to be repeated in
screening requirements for JANTX and JANTXV level devices.
4.3.1 Power burn-in conditions. Power burn-in conditions are as follows: VCB = 10 V dc. Power shall be applied
to achieve TJ = +135°C minimum using a minimum PD = 75 percent of PT maximum. TA = room ambient as defined
in 1.3. With approval of the qualifying activity and preparing activity, alternate burn-in data criteria (hours, bias
conditions, TJ, and mounting conditions) may be used for JANTX and JANTXV quality levels. A justification
demonstrating equivalence is required. In addition, the manufacturing site s burn-in data and performance history will
be essential criteria for burn-in modification approval. Method 3100 of MIL-STD-750 to measure TJ shall be used.
4.3.2 Screening (JANHC and JANKC). Screening of JANHC and JANKC die shall be in accordance with
MIL-PRF-19500, "Discrete Semiconductor Die/Chip Lot Acceptance". Burn-in duration for the JANKC level follows
JANS requirements; the JANHC follows JANTX requirements.
4.3.3 Thermal response (ĆVBE measurements). The ĆVBE measurements shall be performed in
accordance with method 3131 of MIL-STD-750 using the guidelines in that method for determining VH, VCE, IM, IH, tH,
and tMD. The ĆVBE limit used in screen 3c and table I, subgroup 2 shall be set statistically by the supplier over several
die lots and submitted to the qualifying activity for approval.
4.4 Conformance inspection. Conformance inspection shall be in accordance with MIL-PRF-19500 and as
specified herein. If alternate screening is being performed in accordance with MIL-PRF-19500, a sample of screened
devices shall be submitted to, and pass, the requirements of group A1 and A2 inspection only (table E-VIb, group B,
subgroup 1 is not required to be performed again if group B has already been satisfied in accordance with 4.4.2).