MILPRF19500/504F
TABLE I. Group A inspection Continued.
Limit
Inspection 1/
Symbol
Unit
Method
Conditions
Min
Max
Subgroup 3
TA = +150°C
High temperature operation:
Collector to emitter
3041
5.0
mA dc
Bias condition A, VBE = 1.5 V dc
ICEX2
cutoff current
2N6058
VCE = 80 V dc
2N6059
VCE = 100 V dc
Collector to emitter
3071
2.0
V dc
IC = 10 A dc; IB = 40 mA dc;
VCE(sat)3
saturation voltage
pulsed (see 4.5.1)
TA = 55°C
Low temperature operation:
Forward-current
3076
200
VCE = 3 V dc; IC = 10 A dc;
hFE4
transfer ratio
pulsed (see 4.5.1)
Subgroup 4
Pulse response
µs
Turn-on time
2.0
ton
IC = 10 A dc; IB = 40 mA dc
µs
Turn-off time
10
toff
IC = 10 A dc; IB1 = IB2 = 40 mA dc
Magnitude of common
3306
8
80
VCE = 3 V dc; IC = 10 A dc;
|hfe|
emitter small-signal,
f = 1.0 MHz
short-circuit forward- current
transfer ratio
Small-signal, short-circuit
3206
700
hfe
VCE = 3 V dc, IC = 10 A dc;
forward-current transfer ratio
f = 1 kHz
Open-circuit output
3236
350
pF
VCB = 10 V dc; IE = 0;
Cobo
100 kHz ≤ f ≤ 1 MHz
capacitance
See footnotes at end of table.