MIL-PRF-19500/590K
* TABLE I. Group A inspection - Continued.
Inspection 1/
Symbol
Limits
Unit
Method
Conditions
Min
Max
Subgroup 4 - Continued
Low current reverse
4031
See 4.5.5.1 condition B, and
ns
trr1
recovery time
figure 5 herein.
1N6626, U, US
30
1N6627, U, US
30
1N6628, U, US
30
1N6629, U, US
50
1N6630, U, US
50
1N6631, U, US
60
High current reverse
4031
ns
trr2
*
recovery time
2 A, di/dt = 100 A/µs, and
figure 6 herein.
1N6626, U, US
45
1N6627, U, US
45
1N6628, U, US
45
1N6629, U, US
60
1N6630, U, US
60
1N6631, U, US
80
IRM(REC)
Peak recovery current
A
1N6626, U, US
3.5
1N6627, U, US
3.5
1N6628, U, US
3.5
1N6629, U, US
4.2
1N6630, U, US
4.2
1N6631, U, US
5.0
Scope display evaluation
4023
Stable only (see 4.5.4),
n = 116, c = 0
See footnote at end of table.