4.4 Conformance inspection. Conformance inspection shall be in accordance with MIL-PRF-19500 and as
specified herein.
4.4.1 Group A inspection. Group A inspection shall be conducted in accordance with MIL-PRF-19500 and table I
herein.
4.4.2 Group B inspection. Group B inspection shall be conducted in accordance with the conditions specified for
subgroup testing in appendix E, tables E-VIA (JANS) and E-VIB (JAN, JANTX and JANTXV) of MIL-PRF-19500 and
4.4.2.1 and 4.4.2.2 herein. Electrical measurements (end-points) shall be in accordance with table I, subgroup 2
herein. Delta measurements shall be in accordance with table III herein.
4.4.2.1 Group B inspection, appendix E, table E-VIA (JANS) of MIL-PRF-19500. For B5, if a failure occurs,
resubmission shall be at the test conditions of the original sample.
Subgroup
Method
Condition
0°C to +100°C, 25 cycles.
B3
1056
-55°C to +175°C, 100 cycles.
B3
1051
B3
4066
intervals, IO = 0, VRWM = 0.
B4
1037
B5
1027
TJ = +150°C minimum; f = 50 - 60 Hz; n = 45, c = 0; t = 1,000 hours. TA = +55°C
max. . Temporary leads may be added for surface mount devices. For irradiated
devices, include trr as an end-point measurement. Delta trr shall not exceed 60
percent of initial reading. With approval of the qualifying activity, alternate life test
criteria (hours, bias condition, TJ, mounting conditions) may be used.
B6
4081
For surface mount devices (US version), RθJEC ≤ 6.5°C/W.
Peak reverse power, PRM ≥ 318 W for square wave in accordance with method
B8
4065
performed on each sublot; sampling plan n = 10, c = 0, end-points, see 4.4.2.
4.4.2.2 Group B inspection, appendix E, table E- VIB (JAN, JANTX, and JANTXV of MIL-PRF-19500).
Subgroup
Method
Condition
0°C to +100°C, 10 cycles.
B2
1056
-55°C to +175°C, 25 cycles.
B2
1051
B3
1027
4.5.3.1). For irradiated devices, include trr as an end-point measurement. Delta
trr shall not exceed 25 percent of initial reading.
8