MIL-PRF-19500/604B
* TABLE I. Group A inspection.
1/
MIL-STD-750
Limit
Unit
Inspection
Symbol
Method
Conditions
Min
Max
Subgroup 1
2071
Visual and mechanical
examination
Subgroup 2
ĆVSD
*
Thermal impedance
3161
See 4.3.3
See
4.3.3
Breakdown voltage, drain
3407
VGS = 0; ID = 1 mA dc, bias
V(BR)DSS
to source
condition C
2N7272
100
V dc
2N7275
200
V dc
2N7278
250
V dc
2N7281
500
V dc
3403
VDS = VGS, ID = 1 mA dc
VGS(th)1
2.0
4.0
V dc
Gate to source voltage
(threshold)
IGSSF1
+100
nA dc
Gate current
3411
VGS = +20 V dc bias condition C,
VDS = 0
IGSSR1
-100
nA dc
Gate current
3411
VGS = -20 V dc, bias condition C,
VDS = 0
µa dc
IDSS1
25
Drain current
3413
VGS = 0, bias condition C;
VDS = 80 percent of rated VDS
Static drain to source on
3421
VGS = 10 V dc, condition A, pulsed
rDS(on)1
state resistance
(see 4.5.1), Id = Id2
Ω
2N7272
0.18
Ω
2N7275
0.50
Ω
2N7278
0.70
Ω
2N7281
2.50
Static drain to source on
3421
VGS = 10 V dc, condition A, pulsed
rDS(on)2
state resistance
(see 4.5.1), Id = Id1
Ω
2N7272
0.189
Ω
2N7275
0.525
Ω
2N7278
0.735
Ω
2N7281
2.630
Forward voltage
4011
Pulsed (see 4.5.1), Id = Id1; VGS =
VSD
1.8
V dc
0
Subgroup 3
TC = TJ = +125°C
High temperature
operation
IGSS2
±200
nA dc
Reverse gate current
3411
VGS = +20 and -20 V dc, bias
condition C, VDS = 0
IDSS2
1.0
mA dc
Drain current
3413
VGS = 0, bias condition C;
VDS = 100 percent of rated VDS
Drain current
VDS = 80 percent of rated VDS
IDSS3
0.25
mA dc
See footnote at end of table.