MIL-PRF-19500/604B
* TABLE I. Group A inspection - Continued.
1/
MIL-STD-750
Limit
Unit
Inspection
Symbol
Method
Conditions
Min
Max
Subgroup 3 - Continued.
Static drain to source on
3421
VGS = 10 V dc, pulsed (see 4.5.1), Id =
rDS(on)3
state resistance
Id2
Ω
2N7272
0.36
Ω
2N7275
1.10
Ω
2N7278
1.68
Ω
2N7281
6.50
VDS = VGS, ID = 1 mA dc
VGS(th)2
1.0
V dc
Gate to source voltage
3403
(threshold)
TC = TJ = -55°C
Low temperature operation
3403
VDS = VGS, ID = 1 mA dc
VGS(th)3
5.0
V dc
Gate to source voltage
(threshold)
Subgroup 4
ID = ID1, VGS = 10 V dc, RG = 25Ω, VDD =
Switching time test
3472
50 percent of rated VDS
Turn-on delay time
td(on)
2N7272
35
ns
2N7275
35
ns
2N7278
35
ns
2N7281
46
ns
Rise time
tr
2N7272
210
ns
2N7275
140
ns
2N7278
85
ns
2N7281
58
ns
Turn-off delay time
td(off)
2N7272
200
ns
2N7275
172
ns
2N7278
195
ns
2N7281
208
ns
Fall time
tf
2N7272
145
ns
2N7275
80
ns
2N7278
75
ns
2N7281
54
ns
Subgroup 5
Safe operating area test
3474
See figure 4; tp = 10 ms minimum,
VDS = 80 percent of max rated VDS
(VDS ≤ 200)
Electrical measurements
See table I, subgroup 2 herein.
Subgroup 6
Not applicable