MILPRF19500/624E
4.4.2 Group B inspection. Group B inspection shall be conducted in accordance with the tests and conditions
specified for subgroup testing in table EVIA (JANS) or table EVIB (JAN, JANTX, and JANTXV) of
MILPRF19500 and herein. Electrical measurements (end-points) shall be in accordance with table I, subgroup 2
herein. Delta requirements shall be in accordance with the applicable step of 4.6 herein.
4.4.2.1 Quality level JANS (table EVIA of MILPRF19500).
Subgroup
Method
Conditions
VCB ≥ 10 V dc, 2,000 cycles, adjust device current, or power, to achieve a minimum
B4
1037
ĆTJ of +100°C.
B5
2037
Test condition A.
4.4.2.2 Quality levels JAN, JANTX, and JANTXV (table EVIB of MILPRF19500).
Subgroup
Method
Conditions
VCB ≥ 10 V dc, 2,000 cycles, adjust device current, or power, to achieve a minimum
B3
1037
ĆTJ of +100°C.
TA = +200°C.
B6
1032
4.4.3 Group C inspection. Group C inspection shall be conducted in accordance with the conditions specified for
subgroup testing in table EVII of MILPRF19500 and as follows herein. Electrical measurements (end-points) shall
be in accordance with table I, subgroup 2 herein. Delta requirements shall be in accordance with the applicable step
of 4.6 herein.
Subgroup
Method
Conditions
C2
1056
Test condition B.
C2
2036
Test condition A (tension), weight = 10 pounds (4.5 kg), t = 10 seconds.
C5
3131
See 4.3.1.
VCB ≥ 10 V dc, 6,000 cycles, adjust device current, or power, to achieve a minimum
C6
1037
ĆTJ of +100°C.
4.4.4 Group E inspection. Group E inspection shall be conducted in accordance with the conditions specified for
subgroup testing in appendix E, table EIX of MILPRF19500 and as specified in table II herein. Electrical
measurements (end-points) shall be in accordance with table I, subgroup 2 herein. Delta requirements shall be in
accordance with the applicable step of 4.6 herein.
4.5 Method of inspection. Methods of inspection shall be as specified in the appropriate tables and as follows.
4.5.1 Pulse response measurements. The conditions for pulse response measurement shall be as specified in
section 4 of MILSTD750.
6