MIL-PRF-19500/323N
* TABLE I. Group A inspection - Continued.
Inspection 1/
MIL-STD-750
Symbol
Limit
Unit
Method
Conditions
Min
Max
Subgroup 2 - Continued
Forward-current transfer
3076
VCE = 1.0 V dc; IC = 0.1 mA dc
hFE1
ratio
2N3250A,
40
2N3250AUB
2N3251A,
80
2N3251AUB
Forward-current transfer
3076
VCE = 1.0 V dc; IC = 1.0 mA dc
hFE2
ratio
2N3250A,
45
2N3250AUB
2N3251A,
90
2N3251AUB
Forward-current transfer
3076
VCE = 1.0 V dc; IC = 10 mA dc,
hFE3
ratio
pulsed (see 4.5.1)
2N3250A,
50
150
2N3250AUB
2N3251A,
100
300
2N3251AUB
Forward-current transfer
3076
VCE = 1.0 V dc; IC = 50 mA dc,
hFE4
ratio
pulsed (see 4.5.1)
2N3250A,
15
2N3250AUB
2N3251A,
30
2N3251AUB
Current gain linearity
hFE 3 - hFE1
hFE
x 100
hFE 3
2N3250A,
40
%
2N3250AUB
2N3251A,
30
%
2N3251AUB
Collector - emitter
3071
0.25
V dc
IC = 10 mA dc; IB = 1.0 mA dc
VCE(SAT)1
saturated voltage
Collector - emitter
3071
0.50
V dc
IC = 50 mA dc; IB = 5.0 mA dc;
VCE(SAT)2
saturated voltage
pulsed (see 4.5.1)
Base - emitter saturated
3066
0.60
0.90
V dc
Test condition A; IC = 10 mA dc;
VBE(SAT)1
voltage
IB = 1.0 mA dc
Base - emitter saturated
3066
1.20
V dc
VBE(SAT)2
Test condition A; IC = 50 mA dc;
voltage
See footnotes at end of table.