MIL-PRF-19500/323N
4.4.2.3 Group B sample selection. Samples selected from group B inspection shall meet all of the following
requirements:
a. For JAN, JANTX, and JANTXV samples shall be selected randomly from a minimum of three wafers (or from
each wafer in the lot) from each wafer lot. For JANS, samples shall be selected from each inspection lot.
See MIL-PRF-19500.
b. Shall be chosen from an inspection lot that has been submitted to and passed group A, subgroup 2
conformance inspection. When the final lead finish is solder or any plating prone to oxidation at high
temperature, the samples for life test (subgroups B4 and B5 for JANS, and group B for JAN, JANTX, and
JANTXV) may be pulled prior to the application of final lead finish.
4.4.3 Group C inspection. Group C inspection shall be conducted in accordance with the conditions specified for
subgroup testing in table E-VII of MIL-PRF-19500, and as follows. Electrical measurements (end-points) and delta
requirements shall be in accordance with the steps of table IV herein.
4.4.3.1 Group C inspection (JANS), table E-VII of MIL-PRF-19500.
Subgroup
Method
Condition
C2
2036
Test condition E; (not applicable for UB devices).
1,000 hours at VCB = 10 V dc; power shall be applied to achieve TJ = +150°C minimum and
C6
1026
The sample size may be increased and the test time decreased as long as the devices are
stressed for a total of 45,000 device hours minimum, and the actual time of test is at least
340 hours.
4.4.3.2 Group C inspection (JAN, JANTX, and JANTXV), table E-VII of MIL-PRF-19500.
Subgroup Method
Condition
C2
2036
Test condition E; not applicable for UB devices.
C5
3131
C6
Not applicable.
4.4.3.3 Group C sample selection. Samples for subgroups in group C shall be chosen at random from any
inspection lot containing the intended package type and lead finish procured to the same specification which is
submitted to and passes table I tests herein for conformance inspection. When the final lead finish is solder or any
plating prone to oxidation at high temperature, the samples for C6 life test may be pulled prior to the application of
final lead finish. Testing of a subgroup using a single device type enclosed in the intended package type shall be
considered as complying with the requirements for that subgroup.
* 4.4.4 Group D inspection. Conformance inspection for hardness assured JANS and JANTXV types shall include
the group D tests specified in table II herein. These tests shall be performed as required in accordance with
MIL-PRF-19500 and method 1019 of MIL-STD-750 for total ionizing dose, or method 1017 of MIL-STD-750 for
neutron fluence, as applicable (see 6.2 herein), except group D, subgroup 2 may be performed separate from other
subgroups. Alternate package options may also be substituted for the testing provided there is no adverse effect to
the fluence profile.
4.4.5 Group E inspection. Group E inspection shall be conducted in accordance with the conditions specified for
subgroup testing in table E-IX of MIL-PRF-19500 and as specified in table III herein. Electrical measurements (end-
points) and delta requirements shall be in accordance with table IV herein.