MIL-PRF-19500/350L
* TABLE II. Group D inspection.
Inspection 1/ 2/ 3/
MIL-STD-750
Limit
Unit
Symbol
Method
Conditions
Min
Max
Subgroup 1 4/
1017
Neutron exposure Vces = 0 V
Neutron Irradiation
Collector to base
3036
ICBO1
cutoff current
µA dc
2N3867, 2N3867S, 2N3867U4
200
VCB = 40 V dc
µA dc
2N3868, 2N3868S, 2N3868U4
200
VCB = 60 V dc
µA dc
Emitter to base cutoff
3061
200
Bias condition D; VEB = 4 V dc
IEBO1
current
Breakdown voltage,
3011
Bias condition D; IC = 20 mA dc;
V(BR)CEO
collector to emitter
pulsed (see 4.5.1)
2N3867, 2N3867S, 2N3867U4
40
V dc
2N3868, 2N3868S, 2N3868U4
60
V dc
µA dc
Collector to emitter
3041
Bias condition A; VEB = 2.0 V dc
2.0
ICEX1
cutoff current
2N3867, 2N3867S, 2N3867U4
VCE = 40 V dc,
2N3868, 2N3868S, 2N3868U4
VCE = 60 V dc
Forward-current
3076
VCE = 1.0 V dc, IC = 500 mA dc,
[hFE1] 5/
transfer ratio
pulsed (see 4.5.1)
2N3867, 2N3867S, 2N3867U4
[25]
2N3868, 2N3868S, 2N3868U4
[17.5]
Forward-current
3076
VCE = 2.0 V dc, IC = 1.5 A dc,
[hFE2] 5/
transfer ratio
pulsed (see 4.5.1)
2N3867, 2N3867S, 2N3867U4
[20]
200
2N3868, 2N3868S, 2N3868U4
[15]
150
3076
Forward-current
VCE = 3.0 V dc, IC = 2.5 A dc,
[hFE3] 5/
transfer ratio
pulsed (see 4.5.1)
[12.5]
2N3867, 2N3867S, 2N3867U4
[10]
2N3868, 2N3868S, 2N3868U4
Forward-current
3076
[10]
VCE = 5.0 V dc, IC = 3.0 A dc,
[hFE4] 5/
transfer ratio
pulsed (see 4.5.1)
See footnotes at end of table.
15
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business