MIL-PRF-19500/398K
* TABLE II. Group D inspection and end-point limits.
Inspection 1/ 2/ 3/
MIL-STD-750
Limits
Symbol
Unit
Method
Conditions
Min
Max
Subgroup 1 4/
Neutron irradiation
1017
Neutron exposure VCES = 0 V
Collector-base breakdown
3011
Bias condition D; IC = 5 mA dc;
V(BR)CEO
30
V dc
voltage
pulsed (see 4.5.1)
Collector-emitter breakdown
3001
Bias condition D; IC = 100 ľA dc;
V(BR)CEO
60
V dc
voltage
pulsed (see 4.5.1)
V(BR)CEO
3.5
V dc
Emitter-base breakdown
3026
Bias condition D; IE = 100 ľA dc;
pulsed (see 4.5.1)
voltage
Collector-emitter cutoff
3041
Bias condition D; VCB = 28 V dc
ICEO
40
ľA dc
current
Collector-emitter cutoff
3041
Bias condition C; VCE = 55 V dc
ICES1
200
ľA dc
current
Forward-current transfer ratio
3076
VCE = 5 V dc, IC = 50 mA dc;
hFE1 5/
2N3866, 2N3866UB
pulsed (see 4.5.1)
[7.5]
200
2N3866A, 2N3866AUB
[12.5]
200
Forward-current transfer ratio
3076
VCE = 5 V dc, IC = 360 mA dc;
hFE2 5/
2N3866, 2N3866UB
pulsed (see 4.5.1)
2N3866A, 2N3866AUB
[2.5]
[4.0]
Collector-emitter
3071
IC = 100 mA dc, IB = 10 mA dc,
VCE(sat)
1.15
V dc
saturated voltage
pulsed (see 4.5.1)
See footnotes at end of table.