* 4.3.2 Thermal impedance. The thermal impedance measurements shall be performed in accordance with method
3101 or 4081 of MIL-STD-750 using the guidelines in that method for determining IM, IH, tH, tSW (VC and VH where
4.3.3 Burn-in. Burn-in conditions for all quality levels are as follows: method 1038 of MIL-STD-750, test condition
4.4 Conformance inspection. Conformance inspection shall be in accordance with MIL-PRF-19500.
4.4.1 Group A inspection. Group A inspection shall be conducted in accordance with appendix E, table E-V of
MIL-PRF-19500 and table I herein.
* 4.4.2 Group B inspection. Group B inspection shall be conducted in accordance with the conditions specified for
subgroup testing in tables E-VIA (JANS) and E-VIB (JAN, JANTX, and JANTXV) of MIL-PRF-19500 and as follows.
Electrical measurements (end-points) shall be in accordance with table I, subgroup 2 and the applicable step and
footnotes of table III herein.
4.4.2.1 Group B inspection, table E-VIA (JANS) of MIL-PRF-19500.
Subgroup
Method
Condition
B3
4066
surge/minute maximum. IFSM = 400 A dc, IO = 20 A dc.
B4
1037
B5
1038
Condition A, t = 1000 hours, TC = +150°C VR = 80 percent of VRWM (pk) (see
1.3).
B8
1018
Only to be performed when organics or silicones are present in the device
package; n = 3, c = 0.
4.4.2.2 Group B inspection, table E-VIB (JAN, JANTX, and JANTXV) of MIL-PRF-19500.
Subgroup
Method
Condition
B2
4066
surge/minute maximum. IFSM = 400 A dc, IO = 20 A dc.
B3
1036
10