MILPRF19500/553F
4.5.4 Thermal resistance. Thermal resistance measurement shall be performed in accordance with test method
4081 of MILSTD750. Read and record data in accordance with table II herein shall be included in the qualification
report.
a.
IH > rated IO.
b.
tH = 20 seconds minimum.
c.
IM = 50 mA to 250 mA.
tMD = 300 µs maximum.
d.
4.5.5 Reverse current at peak reverse voltage, alternate test. The reverse current at peak reverse voltage test
requirement may be satisfied by performing the reverse energy test of 4.5.2 and measuring breakdown voltage to
ensure VBR ≥ 54 V (pk) with IRM = 2.0 A (pk).
4.5.6 DC intermittent operation life. DC intermittent operation life shall be performed in accordance with test
method 1037 of MILSTD750. A cycle shall consist of an "on" period, when forward current is applied suddenly, not
gradually, to the device for the time necessary to achieve an increase (delta) case temperature of +85°C +15°C, 5°C
followed by an "off" period, when the current is suddenly removed for cooling, the case through a similar delta
temperature. Auxiliary (forced) cooling is permitted during the "off" period only. Forward current or "on" time, within
specific limits, and "off" time may be adjusted to achieve the delta case temperature. Heat sinks shall only be used if,
and to the degree necessary, to maintain test samples within the desired delta temperature tolerance. The heating
time shall be such that 30 s ≤ theating ≤ 180 s. The forward current may be steady-state dc, full-wave rectified dc, or
the equivalent half-sine wave dc, of the specified value. The test duration shall be the specified number of cycles.
Within the time interval of 50 cycles before and 500 cycles after the termination of the test, the sample units shall be
removed from the specified test conditions and allowed to reach room ambient conditions. Specified end-point
measurements for qualification and quality conformance inspections shall be completed within 96 hours after removal
of sample units from the specified test conditions. Additional readings may be taken at the discretion of the
manufacturer.
4.5.7 Inspection conditions. Unless otherwise specified in MILPRF19500 or herein, all inspections shall be
conducted at a TC of 25°C ±3°C.