MIL-PRF-19500/587E
* TABLE I. Group A inspection - Continued.
Inspection 1/
MIL-STD-750
Symbol
Limits
Unit
Method
Conditions
Min
Max
Subgroup 3 - Continued
TA = -55°C
Low temperature
operation:
Forward voltage
4011
1.2
V dc
IF = 400 mA dc; 2 percent duty
VF3
cycle max, 8.3 ms max pulse
width; (pulsed; see 4.5.1)
Subgroup 4
4001
C
20
pF
Capacitance
VR = 4 V dc; f = 1 MHz;
Vsig = 50 mV p-p maximum
Subgroup 5
Not applicable
Subgroup 6 2/
Surge current
4066
Condition A, mounting conditions
*
in accordance with test method
1026 of MIL-STD-750; TA =
25°C; IFSM = 5 A; ten 8.3 ms
surges; 1 surge per minute
Electrical
See table I, subgroup 2.
measurements
1/ For sampling plan, see MIL-PRF-19500.
2/ All devices required by the specified sampling plan shall be randomly selected from the devices subjected to
subgroup 2, 3, and 4.