MIL-PRF-19500/587E
4.4.2.2 Group B inspection, appendix E, table E-VIB (JAN, JANTX, and JANTXV) of MIL-PRF-19500.
Subgroup
Method
Condition
0°C to +100°C, 25 cycles.
B2
1056
-55°C to +175°C, 25 cycles.
B2
1051
Condition A, TA = +25°C, IFSM = 5 A, ten 8.3 ms surges at 1 surge per minute
B2
4066
intervals, superimposed on IO = rated, VRWM = rated. Mounting conditions are
in accordance with method 1026 of MIL-STD-750.
B3
1027
1N6661, US = VRM = 225 V(pk)
1N6662, US = VRM = 400 V(pk)
1N6663, US = VRM = 600 V(pk)
B5
Not applicable
TA = + 175°C (nonoperating). (NOTE: Leaded samples from the same lot may
B6
1032
be used in lieu of US suffix samples for all subgroups.).
4.4.3 Group C inspection. Group C inspection shall be conducted in accordance with the conditions specified for
subgroup testing in appendix E, table E-VII of MIL-PRF-19500. Electrical measurements (end-points) shall be in
accordance with the applicable inspections of table I, subgroup 2 herein. Delta requirements shall be in accordance
with the applicable steps of table III herein.
*
4.4.3.1 Group C inspection, appendix E, table E-VII of MIL-PRF-19500.
Subgroup
Method
Condition
0°C to +100°C, 10 cycles.
C2
1056
-55°C to +175°C, 20 cycles.
C2
1051
*
C2
2036
Lead tension: Test condition A; weight = 6 pounds; t = 15 seconds.
Lead fatigue: Condition E.
NOTE: Not applicable to US-suffix devices.
*
C2
2038
US devices - Condition B, 6 pounds, t = 15s.
C3
Not applicable.
C5
4081
C6
1026
1N6661, US = VRM = 225 V(pk)
1N6662, US = VRM = 400 V(pk)
1N6663, US = VRM = 600 V(pk)
NOTE: Leaded devices from the same lot may be used in lieu of U-suffix
devices.
C7
Not applicable.
8
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business