MILPRF19500/597G
TABLE I. Group A inspection.
Limit
Inspection 1/
Unit
Symbol
Max
Min
Method
Conditions
Subgroup 1
Visual and mechanical
2071
inspection
Subgroup 2
Thermal impedance 2/
3161
See 4.3.1.3
ZθJC
V(BR)DSS
Breakdown voltage,
3407
Bias condition C
100
V dc
VGS = 0 V dc, ID = 1 mA dc,
drain-to-source
VDS ≥ VGS,
VGS(th)1
Gate-to-source
3403
2.0
4.0
V dc
ID = 0.25 mA dc
voltage (threshold)
Bias condition C, VGS = +20 V dc,
IGSSF1
Gate current (forward)
3411
+100
nA dc
VDS = 0
Bias condition C, VGS = 20 V dc,
IGSSR1
Gate current (reverse)
3411
100
nA dc
VDS = 0
µA dc
Bias condition C, VGS = 0 V dc,
IDSS1
Drain current
3413
25
VDS = 80 percent of rated VDS
Ω
Bias condition A, VGS = 10 V dc,
rDS(on)1
Static drain-to-source
3421
0.70
on-state resistance
pulsed (see 4.5.1)
Ω
rDS(on)2
0.80
VGS = 0 V, ID = ID1,
VSD
Forward voltage
4011
1.5
V
pulsed (see 4.5.1)
Subgroup 3
TC = TJ = +125°C
High temperature operation:
IGSS2
Gate current
3411
Bias condition C,
±200
nA dc
VGS = +20 V dc and 20 V dc,
VDS = 0 V dc
Bias condition C, VGS = 0 V dc,
IDSS2
Drain current
3413
0.25
mA dc
VDS = 80 percent of rated VDS
Ω
Bias condition A, VGS = 10 V dc,
rDS(on)3
Static drain-to-source
3421
1.4
on-state resistance
See footnotes at end table.
11
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business