MIL�PRF�19500/598C
TABLE I. Group A inspection � Continued.
Limit
Inspection 1/
Unit
Symbol
Max
Min
Method
Conditions
Subgroup 5
Single pulse unclamped
3470
EAS
inductive switching 3/
Electrical measurements
See subgroup 2 of this table
Safe operating area test for
3474
VDS = 80 percent of rated V(BR)DSS,
power MOSFETs
N-channel
ID = 0.25 A
P-channel
ID = 0.5 A
Electrical measurements
See subgroup 2 of this table and
Subgroup 6
Not applicable
Subgroup 7
Gate charge
3471
Condition B
On-state gate charge
Qg(on)
15
nC
Gate to source charge
Qgs
N-channel
7.5
nC
P-channel
7.0
nC
Gate to drain charge
Qgd
nC
N-channel
7.5
nC
P-channel
8.0
nC
Condition A, di/dt ≤ �100 A/�s,
Reverse recovery time
3473
trr
200
ns
1/
2/
This test is required for the following end-point measurement only (not intended for screen 9, 11, or 13): JANS,
MIL�PRF�19500, group B, subgroups 2 and 3; and table E�VII of MIL�PRF�19500, group C, subgroup 6, and
3/
This test need not be performed in group A if performed in screening.
12
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business