MIL-PRF-19500/613E
TABLE II. Group D inspection - Continued.
MIL-STD-750
Limits
Symbol
Unit
Inspection 1/ 2/ 3/
Min
Max
Method
Conditions
Subgroup 2
Total dose irradiation
1019
Gamma exposure VCES = 64 V,
condition A
Collector to emitter
3011
Bias condition D; IC = 100 mA dc,
V(BR)CEO
80
V dc
breakdown voltage
IB = 0, pulsed (see. 4.5.1)
µA dc
Collector to emitter
3041
Bias condition C;
ICES1
2.0
VCE = 60 V dc; V
cutoff current
BE = 0
Collector to emitter
3041
Bias condition C;
ICES2
2.0
mA dc
VCE = 100 V dc; V
cutoff current
BE = 0
µA dc
Collector to emitter
3041
Bias condition D;
ICEO
100
VCE = 40 V dc; I
cutoff current
B=0
µA dc
Emitter to base
3061
Bias condition D;
IEBO1
2.0
VEB = 4 dc; I
cutoff current
C=0
Emitter to base
3061
Bias condition D;
IEBO2
2.0
mA dc
VEB = 5.5 dc; I
cutoff current
C=0
Forward-current
3076
VCE = 5.0 V dc; IC = 50 mA dc;
[hFE1] 5/
[25]
transfer ratio
pulsed (see 4.5.1)
Forward-current
3076
VCE = 5.0 V dc; IC = 2.5 A dc;
[hFE2] 5/
[35]
200
transfer ratio
pulsed (see 4.5.1)
Forward-current
3076
VCE = 5.0 V dc; IC = 5.0 A dc;
[hFE3] 5/
[20]
transfer ratio
pulsed (see 4.5.1)
Base to emitter
3066
Test condition B; VCE = 5.0 V dc, IC
VBE
1.67
V dc
non-saturated voltage
= 2.5 A dc, pulsed (see 4.5.1)
Base to emitter
3066
Test condition A; IC = 2.5 A dc
VBE(SAT)1
1.67
V dc
saturated voltage
IB = 250 mA dc, pulsed (see 4.5.1)
Base to emitter
3066
Test condition A; IC = 5.0 A dc
VBE(SAT)2
2.53
V dc
saturated voltage
IB = 500 mA dc, pulsed (see 4.5.1)
Collector to emitter
3071
IC = 2.5 A dc; IB = 250 mA dc;
VCE(sat)1
0.86
V dc
saturated voltage
pulsed (see 4.5.1)
Collector to emitter
3071
1.73
V dc
VCE(sat)2
IC = 5.0 A dc; IB = 500 mA dc;
saturated voltage
pulsed (see 4.5.1)
1/
Tests to be performed on all devices receiving radiation exposure.
2/
For sampling plan, see MIL-PRF-19500.
3/
Electrical characteristics apply to all device types unless otherwise noted.
4/
Subgroup 1 is an optional test and must be specified on the purchasing contract when required.
5/
See method 1019 of MIL-STD-750 for how to determine [hFE] by first calculating the delta (1/hFE) from the pre-
and Post-radiation hFE. Notice the [hFE] is not the same as hFE and cannot be measured directly. The [hFE]
value can never exceed the pre-radiation minimum hFE that it is based upon.