MIL-PRF-19500/614J
TABLE I. Group A inspection.
Inspection
Limits
Symbol
Unit
1/
Method
Condition
Min
Max
Subgroup 1
Visual and mechanical
2071
inspection
Subgroup 2
°C/W
Thermal impedance 2/
3161
See 4.3.3
Z θJC
Breakdown voltage
3407
VGS = 0, ID = 1 mA dc,
V (BR)DSS
drain to source
bias condition C
2N7380
100
V dc
2N7381
200
V dc
VDS ≥ VGS, ID = 1.0 mA
Gate to source voltage
3403
VGS(th)1
2.0
4.0
V dc
(threshold)
Gate current
3411
VGS = +20 V dc, VDS = 0,
IGSSF1
+100
nA dc
bias condition C
Gate current
3411
VGS = -20 V dc, VDS = 0,
IGSSR1
-100
nA dc
bias condition C
µA dc
Drain current
3413
VGS = 0, VDS = 80 percent of rated
IDSS1
25
VDS, bias condition C
Static drain to source
3421
VGS = 12 V dc, condition A, pulsed
rDS(on)1
on-state resistance
Ω
2N7380
0.18
Ω
2N7381
0.40
Static drain to source
3421
VGS = 12 V dc, condition A, pulsed
rDS(on)2
on-state resistance
Ω
2N7380
0.20
Ω
2N7381
0.49
Forward voltage
4011
VGS = 0, ID = rated ID1 pulsed (see
VSD
(source drain diode)
2N7380
1.8
V dc
2N7381
1.4
V dc
See footnotes at end of table.