MIL-PRF-19500/276H
* TABLE I. Group A inspection - Continued.
Inspection 1/
MIL-STD-750
Limit
Unit
Symbol
Method
Conditions
Min
Max
Subgroup 3
TA = +125°C
High temperature operation:
µA dc
Reverse blocking current
4211
DC method, condition B
IRBX2
100
2N2323, S, U4
R2 = 1 k ohm
2N2324, S, U4
2N2326, S, U4
2N2328, S, U4
2N2329, S, U4
2N2323A, AS, AU4
R2 = 2 k ohm
2N2324A, AS, AU4
2N2326A, AS, AU4
2N2328A, AS, AU4
2N2329A, AS, AU4
VR = 50 V dc
2N2323, U4, S, A, AU4, AS
VR = 100 V dc
2N2324, U4, S, A, AU4, AS
VR = 200 V dc
2N2326, U4, S, A, AU4, AS
VR = 300 V dc
2N2328, U4, S, A, AU4, AS
2N2329, U4, S, A, AU4, AS
VR = 400 V dc
µA dc
Forward blocking current
4206
DC method, condition B
IFBX2
100
2N2323, S, U4
R2 = 1 k ohm
2N2324, S, U4
2N2326, S, U4
2N2328, S, U4
2N2329, S, U4
2N2323A, AS, AU4
R2 = 2 k ohm
2N2324A, AS, AU4
2N2326A, AS, AU4
2N2328A, AS, AU4
2N2329A, AS, AU4
VFBX = 50 V dc
2N2323, U4, S, A, AU4, AS
VFBX = 100 V dc
2N2324, U4, S, A, AU4, AS
VFBX = 200 V dc
2N2326, U4, S, A, AU4, AS
VFBX = 300 V dc
2N2328, U4, S, A, AU4, AS
2N2329, U4, S, A, AU4, AS
VFBX = 400 V dc
See footnotes at end of table.