MIL-PRF-19500/276H
* TABLE I. Group A inspection - Continued.
Inspection 1/
MIL-STD-750
Limit
Unit
Symbol
Method
Conditions
Min
Max
Subgroup 3 - Continued.
µA dc
Forward blocking current
4206
DC method, condition B
IFBX3
5
2N2323, S, U4
R2 = 1 k ohm.
2N2324, S, U4
2N2326, S, U4
2N2328, S, U4
2N2329, S, U4
2N2323A, AS, AU4
R2 = 2 k ohm.
2N2324A, AS, AU4
2N2326A, AS, AU4
2N2328A, AS, AU4
2N2329A, AS, AU4
VFBX = 50 V dc
2N2323, U4, S, A, AU4, AS
VFBX = 100 V dc
2N2324, U4, S, A, AU4, AS
VFBX = 200 V dc
2N2326, U4, S, A, AU4, AS
VFBX = 300 V dc
2N2328, U4, S, A, AU4, AS
2N2329, U4, S, A, AU4, AS
VFBX = 400 V dc
Gate trigger voltage and
4221
V2 = VFBX = 6 V dc;
current
RL = 100 ohms
2N2323, S, U4
Re = 1 k ohm
VGT2
1.0
V dc
µA dc
2N2324, S, U4
350
IGT2
2N2326, S, U4
2N2328, S, U4
2N2329, S, U4
2N2323A, AS, AU4
Re = 2 k ohm
VGT2
0.8
V dc
µA dc
2N2324A, AS, AU4
75
IGT2
2N2326A, AS, AU4
2N2328A, AS, AU4
2N2329A, AS, AU4
See footnotes at end of table.