4.4.2 Group B inspection. Group B inspection shall be conducted in accordance with the tests and conditions
specified for subgroup testing in appendix E, table E-VIA (JANS) and table E-VIB (JAN, JANTX, and JANTXV) of
MIL-PRF-19500. End-point electrical measurements shall be in accordance with table I, subgroup 2 herein. Delta
measurements shall be as specified in table IV herein.
* 4.4.2.1 Group B inspection, appendix E, table E-VIA (JANS) of MIL-PRF-19500. For B5, if a failure occurs,
resubmission shall be at the test conditions of the original sample.
Subgroup
Method
Condition
*
B3
4066
1 minute intervals, superimposed on IO = 2 A dc, VRWM = rated VRWM
(see col. 3 of 1.3).
B4
1037
B5
1027
t = 1,000 hours; TA = 55°C max. For irradiated devices, include trr as an end-point
measurement.
Peak reverse power. PRM ≥ 636 W for square wave in accordance with test
B8
4065
performed on each sublot; sampling plan n = 10, c = 0, electrical end-points, see
table I, subgroup 2 herein.
4.4.2.2 Group B inspection, appendix E, table E-VIB (JAN, JANTX and JANTXV of MIL-PRF-19500).
Subgroup
Method
Condition
B3
1027
measurement.
7