MILPRF19500/427P
* TABLE I. Group A inspection.
Symbol
Limits
Inspection 1/
Unit
Method
Conditions
Min
Max
Subgroup 1
Visual and mechanical
2071
inspection
Subgroup 2
°C/W
Thermal impedance 2/
3101
See 4.3.1
ZθJX
Forward voltage
4011
VF1
0.6
1.1
V
duty cycle = 2 percent maximum
Forward voltage
4011
VF2
0.8
1.3
V
tp ≤ 8.3 ms, 2 percent maximum
duty cycle
µA dc
Reverse current leakage
4016
DC method or equivalent pulse;
0.5
IR1
VR = rated VRWM (see col. 4 of
IR = 50 µA dc
Breakdown voltage
4021
VBR
1N5614, US
220
V
1N5616, US
440
V
1N5618, US
660
V
1N5620, US
880
V
1N5622, US
1,100
V
Subgroup 3
TA = +125°C
High temperature
operation:
µA dc
Reverse current
4016
DC method or equivalent pulse;
25
IR2
leakage
VR = rated VRWM (see col. 4 of
TA = -55°C
Low temperature
operation
Forward voltage
4011
VF3
1.5
V
tp ≤ 8.3 ms, 2 percent maximum
duty cycle
Subgroup 4
µs
Reverse recovery time
4031
Condition B1
2
trr
Scope display
4023
See 4.5.2; n = 116, c = 0
Subgroup 5
Not applicable
See footnotes at end of table.
11
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business