MIL-PRF-19500/429N
* TABLE I. Group A inspection - Continued.
Inspection 1/
Symbol
Limits
Unit
Method
Conditions
Min
Max
Subgroup 4
Reverse recovery time
4031
Condition B1
trr
1N5615, US
150
ns
1N5617, US
150
ns
1N5619, US
250
ns
1N5621, US
300
ns
1N5623, US
500
ns
Capacitance
4001
C
VR = 12 V dc, 0.1 < f < 1.0
MHz
1N5615, US
45
pF
1N5617, US
35
pF
1N5619, US
25
pF
1N5621, US
20
pF
1N5623, US
15
pF
Scope display evaluation
4023
See 4.5.4; n = 116, c = 0
Subgroup 5
Not applicable
Subgroup 6
Forward surge
4066
Condition A, IFSM = 25 A (pk);
*
ten surges of 8.3 ms each at 1
minute intervals, IO = 750 mA
dc; VR = rated VRWM (see col.
+100°C for surface mount
devices (US version)).
Electrical measurement
See table I, subgroup 2 except
thermal impedance.
Subgroup 7
Not applicable
For sampling plan, see MIL-PRF-19500.
1/
2
This test required for the following end-point measurements only:
Group B, subgroups 3, 4, and 5 (JANS).
Group B, subgroups 2 and 3 (JAN, JANTX, and JANTXV).
Group C, subgroup 2 and 6.
Group E, subgroup 1.
13
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business