MIL-PRF-19500/444N
4.3.4 JAN testing. JAN level product will have temperature cycling and thermal impedance testing performed in
accordance with MIL-PRF-19500, JANTX level screening level requirements.
4.4 Conformance inspection. Conformance inspection shall be in accordance with MIL-PRF-19500 and as
specified herein.
4.4.1 Group A inspection. Group A inspection shall be conducted in accordance with MIL-PRF-19500 and table I
herein.
4.4.2 Group B inspection . Group B inspection shall be conducted in accordance with the conditions specified for
subgroup testing in table E-VIa (for JANS) and table E-VIb (for JAN, JANTX, and JANTXV) of MIL-PRF-19500, and
as follows. Electrical measurements (end-points) shall be in accordance with table I, subgroup 2 herein.
4.4.2.1 Group B inspection, table E-VIa (JANS) of MIL-PRF-19500.
Subgroup
Method
Condition
B3
1051
Required for UB.
See 4.5.4
Preconditioning for temperature cycling.
*
B3
IO1 at rated VRWM; f = 60 Hz; TA = room ambient as defined in 4.5 of
B4
1037
MIL-STD-750; ton = toff = 3 minutes minimum for 2,000 cycles.
HTRB in accordance with 4.3.1.
B5
1038
RθJL = 250°C/W .375 inch (9.52 mm) lead length (non-surface mount).
B6
4081
4.4.2.2 Group B inspection, table E-VIb (JAN, JANTX and JANTXV) of MIL-PRF-19500.
Subgroup
Method
Condition
See 4.5.4
Preconditioning for temperature cycling.
*
B2
0°C to +100°C, 10 cycles (glass diodes only), n = 22, c = 0.
B2
1056
-55°C to +150°C, 25 cycles, n = 22, c = 0.
B2
1051
B3
1038
HTRB, in accordance with 4.3.1.
*
B4
2101
See 4.5.3 (Scribe and break not applicable for UB)
*
B4
2075
See 4.5.3.1 (Not applicable to glass packages)
TA = +150°C.
B6
1032
10