MIL-PRF-19500/595K
TABLE I. Group A inspection - Continued.
Inspection
MIL-STD-750
Limits
Symbol
Unit
1/
Method
Condition
Min
Max
Subgroup 5
Safe operating area test
3474
See figure 7; tp = 10 ms, VDS = 80
(high voltage)
percent of rated VBR(DSS), VDS =
200 V maximum
Electrical
See table I, subgroup 2
measurements
Subgroup 6
Not applicable
Subgroup 7
Gate charge
3471
Condition B
On-state gate charge
Qg(on)
2N7236, 2N7236U
60
nC
2N7237, 2N7237U
60
nC
Gate to source charge
Qgs
2N7236, 2N7236U
13
nC
2N7237, 2N7237U
15
nC
Gate to drain charge
Qgd
2N7236, 2N7236U
35.2
nC
2N7237, 2N7237U
38
nC
Condition A. di/dt 100 A/s, VDD
trr
Reverse recovery time
3473
30 V,
ID = ID1, (see 1.3)
2N7236, 2N7236U
280
ns
2N7237, 2N7237U
440
ns
1/
For sampling plan, see MIL-PRF-19500.
2/
This test required for the following end-point measurements only:
Group B, subgroups 2 and 3 (JAN, JANTX, and JANTXV).
Group B, subgroups 3 and 4 (JANS).
Group C, subgroups 2 and 6.
Group E, subgroup 1.
14
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business