MIL-PRF-19500/182H
* TABLE II. Group D inspection and end-point limits.
Symbol
Unit
Inspection 1/ 2/ 3/
MIL-STD-750
Limits
Method
Conditions
Min
Max
Subgroup 1 4/
Neutron irradiation
1017
Neutron exposure VCES = 0 V
Collector to base cutoff
3036
Bias condition D; VCB = 120 V dc;
ICBO1
200
µA dc
current
pulsed (see 4.5.1)
Emitter to base cutoff
3061
Bias condition D; VEB = 7.0 V dc;
IEBO1
200
µA dc
current
pulsed (see 4.5.1)
Breakdown voltage,
3011
Bias condition D; IC = 30 mA dc;
V(BR)CEO
80
V dc
collector - emitter
pulsed (see 4.5.1)
Breakdown voltage,
3011
Bias condition D; IC = 10 mA dc;
V(BR)CER
100
V dc
collector - emitter
Collector to base cutoff
3036
Bias condition D, VCB = 90 V dc
ICBO2
20
ηA dc
current
Emitter - base cutoff
3061
Bias condition D; VEB = 5 V dc
IEBO2
20
ηA dc
current
Collector emitter
3071
IC = 150 mA dc; IB = 15 mA dc;
VCE(sat)1
5.75
V dc
saturated voltage
pulsed (see 4.5.1)
Collector emitter
3071
IC = 50 mA dc; IB = 5 mA dc;
VCE(sat)2
1.38
V dc
saturated voltage
pulsed (see 4.5.1)
Base - emitter saturated
3066
Test condition A; IC = 150 mA dc;
VBE(sat)1
1.50
V dc
voltage
1.38
V dc
Base - emitter saturated
3066
Test condition A; IC = 50 mA dc;
VBE(sat)2
voltage
Forward-current transfer
3076
VCE = 10 V dc, IC = 0.1 mA dc,
[hFE1] 5/
[10]
ratio
pulsed (see 4.5.1)
Forward-current transfer
3076
VCE = 10 V dc, IC = 10 mA dc,
[hFE2] 5/
[17.5]
ratio
pulsed (see 4.5.1)
Forward-current transfer
3076
VCE = 10 V dc, IC = 150 mA dc,
[hFE3] 5/
[20]
120
ratio
pulsed (see 4.5.1)
See footnotes at end of table.
14
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business