MILPRF19500/472F
TABLE I. Group A inspection Continued.
Limit
Inspection 1/
Symbol
Unit
Method
Conditions
Min
Max
Subgroup 4 Continued.
Pulse response
Turn-on time
3251
Test condition A, VCC = 30 V dc;
ton
IC = 5.0 A dc
µs
2N6350, 2N6352
See figure 4
0.5
µs
2N6351, 2N6353
See figure 5
0.5
Turn-off time
3251
Test condition A, VCC = 30 V dc;
toff
IC = 5.0 A dc
µs
2N6350, 2N6352
See figure 4
1.2
µs
2N6351, 2N6353
See figure 5
1.2
Subgroup 5
TC = +100°C; t ≥ 1.0 s, 1 cycle;
Safe operating area
3051
(continuous dc)
(for types 2N6350 and
RB2E = 100 ohms
2N6351 only)
Test 1
(2N6350, 2N6351)
VCE = 1.5 V dc; IC = 3.3 A dc
Test 2
(2N6350, 2N6351)
VCE = 30 V dc; IC = 167 mA dc
Test 3
(2N6350)
VCE = 80 V dc; IC = 35 mA dc
Test 4
(2N6351)
VCE = 150 V dc; IC = 13 mA dc
See footnotes at end of table.
13
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business